Addionics, a developer of three-dimensional porous current collectors for lithium-ion batteries, announced on November 18, 2026, that cells using its architecture achieved approximately 3.5 times the cycle life of reference cells in a case study at Avrion Battery Labs Inc. End of life was defined as 80% state of health.
Avrion fabricated two groups of 18650 cylindrical cells with NMC811 cathodes and graphite anodes. One group used conventional current collectors, while the other incorporated Addionics 3D porous current collectors. The laboratory used roll-to-roll electrode coating and tested the cells with ultra-high precision coulometry and electrochemical impedance measurements. Cells rested for 48 hours after every 20 cycles.
Addionics Reports 3.5 Times Longer Cell Cycle Life
Porous current collectors extended cycle life and accelerated capacity recovery by improving electrolyte and salt mobility inside the cell.
Commercial model: 60% to 80% usable window means a third more energy or approximately 25% less battery capacity.
The Addionics cells recovered in less than two hours during initial rest periods and in less than 12 hours by cycle 200. Reference cells required more than 48 hours to recover after the first 20 cycles. According to Addionics, the results are consistent with faster equilibration of electrolyte salt concentration, although direct measurements of salt distribution are planned to test the proposed mechanism.
Sustained cycling can create uneven salt distribution inside lithium-ion cells when electrolyte and salt ion mobility are limited. These concentration gradients can increase resistance, reduce accessible capacity and contribute to lithium plating. Conventional metal foil current collectors block direct electrolyte transport between electrode layers, resulting in longer redistribution pathways within a wound cell.
Addionics’ porous architecture introduces through-plane pathways intended to shorten the distance over which electrolyte and salt must redistribute. The company said reducing diffusion length can substantially shorten relaxation time, with the effect expected to become more significant in larger-format cells. The architecture is intended for operating profiles with repeated cycling and limited rest, including autonomous fleets and robotics.
Addionics also tested 18650 cells at temperatures down to -10 °C at Avrion, where the company reported improved performance at high rates and low temperatures. Follow-up work will examine the proposed transport mechanism and other conditions, including larger cell formats and thicker electrodes.